The daily care of 5-inch submersible pumps mainly includes the following aspects:
Regular inspection and replacement of seals: Before each use, various seals of the submersible pump must be checked to ensure that they are not loose or damaged. If the seal is found to be loose, it should be tightened in time; if the seal is damaged, it should be replaced with a new one in time. After every 50 hours of work, the submersible pump should be lifted out of the ground and the seal should be inspected.
Regular replacement of lubricating oil: For oil-immersed submersible pumps, the oil in the sealing chamber should be replaced after 500 hours of work, and the oil in the motor cavity should be replaced after one year of work. After a wet submersible pump has been running continuously for 2000 hours, the lubricating oil needs to be replaced once, generally lithium-based grease.
Regular rust removal and maintenance: After one year of use, the submersible pump should be checked for rust, rust should be removed, and a layer of anti-rust paint should be applied for protection. After every two years of use, a comprehensive inspection should be carried out, all parts should be disassembled for cleaning, lubrication, and reassembly.
Storage and maintenance: When the submersible pump is not used for a long time, it should be lifted to the ground, wiped dry, and hung in a dry and ventilated room. If placed in water, run it for at least 30 minutes every 15 days to check its function and adaptability.
Measure the insulation resistance value: Use a 500V or 1000V megohmmeter to measure the insulation resistance value of the stator winding of the electric pump to the casing, and ensure that it is above 1 megohm (the minimum shall not be less than 0.5 megohm), otherwise the winding should be repaired or dried.
Refueling and oil change: The sealing oil of the submersible electric pump must be replaced once every 1000 hours of operation, and the oil inside the motor must be replaced once a year. For water-filled submersible pumps, the upper and lower end covers, the skeleton oil seals in the bearing chamber, and the lithium-based lubricating oil must be replaced regularly to ensure good lubrication.
Replace the sealing box in time: If it is found that there is a lot of water leaking into the electric pump (normal leakage is 0.1mL/h), the sealing box should be replaced in time and the insulation resistance value of the motor winding should be measured. If the insulation resistance value is lower than 0.5 megohm, drying treatment is required.
Other maintenance measures: Submersible pumps should be maintained once a year (or after 2500 cumulative hours of operation), including disassembling the pump motor, cleaning all parts, removing scale and rust, checking their integrity, and promptly repairing or replacing damaged parts; replacing the lubricating oil in the sealing chamber and the motor.